HUATEC GROUP CORPORATION export@huatecgroup.com 86-10-82921131

HUATEC GROUP CORPORATION Profil Perusahaan
Produk
Rumah > Produk > Penjelajah pipa sinar-X > PET Pipeline Crawler X Ray Machine D7 D4 Industrial Radiography Film

PET Pipeline Crawler X Ray Machine D7 D4 Industrial Radiography Film

Rincian produk

Tempat asal: Beijing

Nama merek: HUATEC

Sertifikasi: ISO, CE, GOST

Nomor model: Film radiasi D7 D4

Syarat Pembayaran & Pengiriman

Kuantitas min Order: 500 pcs

Kemasan rincian: paket standar ekspor

Waktu pengiriman: 1-4 hari

Syarat-syarat pembayaran: T/T, PayPal, Western Union

Menyediakan kemampuan: 5000000pcs per bulan

Dapatkan Harga Terbaik
Rincian produk
Menyoroti:

PET industrial x ray film HUATEC

,

d7 industrial radiography film

,

d4 industrial radiography film

Bahan:
PELIHARAAN
Jenis:
D7
nama:
Film Sinar-X Industri
Ukuran:
Ukuran apapun
Paket:
Pengemasan Vakum
Merek:
Huatec
Bahan:
PELIHARAAN
Jenis:
D7
nama:
Film Sinar-X Industri
Ukuran:
Ukuran apapun
Paket:
Pengemasan Vakum
Merek:
Huatec
Deskripsi Produk

Pipeline Crawler X-Ray Machine Industrial X-Ray Film D7 D4

 

X ray film applications:
This film is suitable for different NDT applications such as: medium thickness heavy metals and alloys, fairly thick light metals and alloys, and also suitable for NDT of heavy metal parts having thick section when exposed with high-energy radiation. The film is especially suited to high temperature automatic processing. This product is compatible with international norms.

  • Welding and casting
  • Defense industry
  • Aerospace and aircraft industry
  • Composite materials
  • Multiple film techniques

 

Product name and model specification

Model Specification

D4,D4-D,H4,LA400,D5,D5-D,

D7,D7-D,H7,H7-D

356mm×432mm(14in.×17in.),305mm×381mm(12in.×15in.),260mm×360mm (10in. ×14in.),70mm×300mm,80mm×150mm,80mm×240mm,80mm×300mm,80mm×360mm, 100mm×356mm,195mm×275mm,70mm×200m,80mm×100m,80mm×200m

Other specifications and packing capacity can also be provided according to customer requirements.

 

Features and uses

Industrial X-ray film is a kind of high resolution and high image resolution film which is widely used in nondestructive flaw detection. The film has high sensitivity, high contrast, high definition,

 

It can be directly or with lead sensitization screen for X or γ ray exposure. It is suitable for electronic components, synthetic materials, casting and casting, welding, etc.

 

NDT testing for shipbuilding, national defense and nuclear industry, aerospace and aviation industry, etc. Using blue polyester sheet base, two sides coated with emulsion layer, layer and

 

Protective layer. This film has rich layers, high image resolution and good definition. This film can be processed at room temperature, also can be processed by high temperature machine.

 

Features and uses

PET Pipeline Crawler X Ray Machine D7 D4 Industrial Radiography Film 0  GB/T19348.1 EN 584.1 ASTME 1815-08 ISO 11699-1
D4,D4-D,H4 C3 C3 C3
D5,D5-D C4 C4 C4
D7,LA400,D7-D,H7,H7-D C5 C5 C5

 

Product performance

Name of index unit D4,D4-D H4 LA400 D5,D5-D D7,D7-D,H7,H7-D
Density of fog --  ≤0.10 ≤0.10 ≤0.10 ≤0.10 ≤0.12
Contrast factor “r” --  ≥4.0 ≥3.0 ≥3.2 ≥4.0 ≥3.5
ISO “S” --  ≥1.5 ≥1.0 ≥0.6 ≥1.5 ≥2.0
Alkali soluble time Minutes ≥10
Scratch resistance in processing N ≥0.8

 

Safety lighting and washing processing

The safety operating light in the darkroom of this film is a crimson safety light with a 15W bulb. When the film is used for unsealing, the lamp distance is generally above 1.2 meters. Cumulative illumination time

 

No more than 40 minutes. The exposed sample should be flushed within 2h. The washing process is shown in the table below.

Flush the way Other countries Temperature / ℃ Development time /min Fixed time /min Dry / ℃ transshipment

ml/m2
Manual D-19b 20±0.5 5±1 10 Natural drying 300
Machine wash G-30 29±1 1.5~2 2 45~55

 

 

Main film working curve

 

D7 film aluminum working curve:                                             D7 film steel working curve:

PET Pipeline Crawler X Ray Machine D7 D4 Industrial Radiography Film 1

 

D4 film aluminum working curve:

PET Pipeline Crawler X Ray Machine D7 D4 Industrial Radiography Film 2

Exposure and flushing conditions:

Shooting Washing
X-ray machine GE E320 washing machine protec
Lead screen 0.03mm Medicine set President of G - 30
FFD 1m Automatic Flushing 8 minutes
density 2.5 Developing temperature 28 ℃

 

 

 

 

 

 

 

 

 

 

 

Storage and shelf life

 

This film should be stored in a low temperature dry place, the best storage conditions are temperature 10℃ ~ 23℃, relative humidity 30% ~ 65%. Should be strictly avoided in high temperature, high

 

Stored in wet, radioactive and chemical gases, avoid to store in the same room with processing liquid medicine, and should be used within the validity period, product shelf life of 30 months.

 

Matters needing attention

 

1. The film stored at low temperature should be taken out 2 hours in advance before use, and placed at room temperature for more than 2 hours to ensure the temperature of the film and the use environment

 

The temperature balance is consistent, and then open the film packaging, in order to avoid the formation of water vapor on the surface of the film caused by the adhesion between the films and affect the film picture effect,

 

To ensure the normal use of film.

 

2. The film should be unsealed, loaded and rinsed under the safety lamp. The film should not be exposed for too long under the safety lamp

 

Contaminated film, film should be handled with care to avoid friction. After unsealing, the film should be used up as soon as possible, and the unused film should be sealed according to the original package.