Detektor Cacat Ultrasonik
-
Pengukur Ketebalan Ultrasonik
-
Pengukur Ketebalan Lapisan
-
Penguji Kekerasan Portabel
-
Detektor Cacat Sinar X
-
Penjelajah pipa sinar-X
-
Detektor Liburan
-
Pengujian Partikel Magnetik
-
Peralatan Pengujian Arus Eddy
-
Pengujian penetran
-
Durometer Pantai
-
Penguji Kekerasan Brinell
-
alat uji kekerasan rockwell
-
Penguji Kekerasan Mikro Vickers
-
Penguji Kekerasan Bahan
-
Pengukur getaran
-
alat uji kekasaran permukaan
-
Proyektor Profil
-
Gloss Meter
-
Palu uji beton
-
Laser Infrared Thermometer
-
BobBlok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2 -
WilliamBlok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2 -
tomBlok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2 -
LeoBlok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
X-Ray Directional Radiographic Inspection Machine Ceramic Tube Penetrant 50mm
Hubungi saya untuk sampel gratis dan kupon.
Ada apa:0086 18588475571
Wechat wechat: 0086 18588475571
Skype: sales10@aixton.com
Jika Anda memiliki masalah, kami menyediakan 24 jam bantuan online.
x| Output | 170-320kV | Input | 2.5KW |
|---|---|---|---|
| Tempat fokus | ukuran 2,5x2,5 | Penetrasi maksimal | 55mm |
| Bahan | Baja | Sudut Radiasi | 40±5° |
| Penggunaan | Pengujian Sinar-X Industri, pengujian las, Mesin pengujian sinar-X industri | Sumber daya listrik | AC220V±10%,50HZ |
| Aplikasi | Pengujian Sinar-X Industri, deteksi jahitan las | Jaminan | 12 bulan |
| Waktu paparan | 5 menit | Ukuran pengontrol | Ukuran 350*290*170mm |
| Ukuran pembangkit | Ukuran 335×335×700mm | Berat Generator | 43Kg |
| Tabung | Keramik | ||
| Menyoroti | welding x ray machine,industrial x ray machine,x ray inspection equipment |
||
320KV Ceramic tube penetrant 40mm Directional Radiographic inspection machine
Main technical parameters
|
ITEM |
XXG3205 | ||
| Max Penetration thickness Steel (A3) | 55mm | ||
| Focal Distance | 600mm | ||
| Exposure Time | 5min | ||
| Film Type | Agfa D7 | ||
|
Double lead foil Intensifying screen |
0.03 | ||
| Darkroom Disposal | 20±2℃ | ||
| Development | 5minutes | ||
| Blackness | 1.5 | ||
| Input | Voltage (V) | 220V±10% 50―60Hz | |
| Capacity (KVA) | 3.2 | ||
| Output | Tube voltage (KVP) | 170-320Kv | |
| Tube current (mA) | 5 | ||
| Stability | ±1% | ||
|
X-RAY Tube |
Focus mm2 | 2.5×2.5 | |
| Radiation Angle | 40±5° | ||
| Sensitivity | k≤1.8% | ||
| Operation Mode | Intermittent operation, Radiating time to cooling time is 1:1 | ||
|
X-Ray Controller |
Dimension | 350×290×160 | |
| Weight | 11kg | ||
| Circuit Structure | Micro-computer control ,Modular structure,Voice prompt | ||
|
X-RAY Generator |
Cooling | Force air cooling | |
| Insulation | SF6 Gas Insulation | ||
| Working Pressure | 0.35Mpa-0.45Mpa | ||
| Dimension | 335×335×700 | ||
| Weight (kg) | 43kg | ||
| Working Temperature | -10℃―+40℃ | ||
Standard Delivery
| Directional glass X-ray tube | 1 Pcs | |
| Generator | 1 Set | |
| High voltage joins cable | 1 Pcs | 25 Meters |
| Controller | 1 Set | |
| Power cable | 1 Pcs | 10 Meters |
| Grounding cable | 1 Pcs | 5 Meters |
| Accessories | 1 Set | |
| (Including: alarm lamp,1 Pcs; lead letter, 1 box; Film dark cassettes 5 pcs; intensifying screen 5 pcs; Wire penetrameter (IQI) 1 set; fuse1 pc) | ||
![]()
![]()
![]()
System Installation
1.Check and count all goods to be received per the packing list. And then check the quality of the parts for damage,lost and mistake.
2.Keep the controller in a flat,dry and dustless place, switch off the power and connect the power cable.
(Note:
The power supply of the unit is single phase 220V±10% 50-60HZ)
3.If necessary,one end of earth wire can be connected to the earth terminal of the controller and the other end to the special grounding wire.
4.Connect controller to x-ray generator by special 9 cores cable,and form better contact.
5.Check the gas pressure gauge on x-ray generator and make sure it range from 0.35Mpa to 0.45Mpa.If not,the unit is not allowed to turn on so as to avoid any damage to the x-ray generator.
Working Principle
This machine is composed of intelligent controller-ray generator, power cable and connecting cable.
1.The controller will consist of the following sections:
Front Panel: LED display, status and failure indicator, touch keyboards (see the introduction of control panel)
Side Panel: power cable socket and connecting cable socket, power switch,key switch, fuse socket, warning lamp and wire connecting terminal of door-machine interlock.
Internal Circuit: power circuit, rectifying circuit, filter circuit, inverter circuit, control circuit and other circuited.
2.The x-ray generator will consist of the following sections:
X-ray tube, High voltage transformer, Temperature relay, Gas pressure gauge and Cooling fan etc.
3.The schematic diagram of the complete machine:
Optional accessories: