• HUATEC GROUP CORPORATION
    Bob
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    tom
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Leo
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
Kontak Person : Noah
Nomor telepon : +8613911115555
Ada apa : +8613910983110

Radiometer dosimeter Industrial X-Ray Flaw Detector gamma NDT radiation detection

Tempat asal Beijing
Nama merek HUATEC
Sertifikasi ISO, CE, GOST
Nomor model FJ-6000
Kuantitas min Order 1 PCS
Harga around USD200
Kemasan rincian paket standar ekspor
Waktu pengiriman 1-4 hari
Syarat-syarat pembayaran T/T, PayPal, Western Union
Menyediakan kemampuan 500pcs per bulan

Hubungi saya untuk sampel gratis dan kupon.

Ada apa:0086 18588475571

Wechat wechat: 0086 18588475571

Skype: sales10@aixton.com

Jika Anda memiliki masalah, kami menyediakan 24 jam bantuan online.

x
Detail produk
Menyoroti

welding x ray machine

,

industrial x ray machine

Tinggalkan pesan
Deskripsi Produk

 

 

Digital radiometer, dosimeter, high accuracy personal dosimeter,radiation alarm meter

 

Purpose of use:

Measurement of personal gamma and X-ray radiation equivalent dose rate(EDR)

Measurement of personal gamma and X-ray radiation equivalent dose(ED)

Alarm of exceeded programmed threshold levels

 

Application:

Nuclear facilities around environmental radiation detection

 

The soil surface radiation pollution detection

 

Agricultural radiation pollution detection

 

Ore, building materials radioactive detection

 

Personal dose monitoring alarm

 

Industrial X, gamma NDT radiation detection

 

Radiation medical treatment place radiation detection

 

Cobalt source, electronic accelerator irradiation place radiation detection

 

Radioactive radiation laboratory detection

 

Specification:

1,GM counter

2,High sensitivity, response to background of envionment

3,Test γ,χ readiation.

4,Testing range:dose rate:0.01usv/h—5msv/h

cumulate dose:big LCD 000.01—999.99msv

5,Dose rate response:<±30%(50KeV—1.3MeV).

6,Error:<±10%(137Cs 662 KeVγ 1msv/h).

7,Alarm response time:≤3 second

8,Alarm function

Dose rate alarm for each setting of 0.5,1.0,2.5,10,30,50usv/h.

9,Memory of 1000000 dose rate, memory keeps forever

10,Low voltage indicator

11,Working temperature: -30 ℃~60 ℃

12 Working humidity: 95%±3% (40℃