• HUATEC GROUP CORPORATION
    Bob
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    tom
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Leo
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
Kontak Person : Noah
Nomor telepon : +8613911115555
Ada apa : +8613910983110

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter

Tempat asal Beijing
Nama merek HUATEC
Sertifikasi ISO, CE, GOST
Nomor model FJ-3501
Kuantitas min Order 1 PCS
Kemasan rincian paket standar ekspor
Waktu pengiriman 1-4 hari
Syarat-syarat pembayaran T/T, PayPal, Western Union
Menyediakan kemampuan 500pcs per bulan

Hubungi saya untuk sampel gratis dan kupon.

Ada apa:0086 18588475571

Wechat wechat: 0086 18588475571

Skype: sales10@aixton.com

Jika Anda memiliki masalah, kami menyediakan 24 jam bantuan online.

x
Detail produk
Detektor Penghitung GM (dikompensasi) Jarak pengukuran dosis setara kumulatif: Hp(10)0.0μsv-9999msv
Tingkat dosis setara Hp(10)0,1μSv/jam-100mSv/jam Kesalahan relatif <±15% (137Cs) (10uSv/jam-50msv/jam)
Respon energi 50KeV-1.3MeV, kesalahan 30% Respon sudut referensi 137Cs tidak melebihi arah kalibrasi ±30% pada 0°-90°
Ukuran penampilan 50 (gaya)×72 (panjang)×14 (tebal) Berat badan 60G
Menyoroti

x ray inspection equipment

,

industrial x ray machine

Tinggalkan pesan
Deskripsi Produk

HUATEC FJ-3501 Personal Dosimeter

 

Product introduction:

FJ-3501 Personal Dosimeter is a smart pocket instrument that monitors x-rays and γ rays and can read individual doses and individual dose rates directly. Within the measuring range, the alarm threshold can be fixed or preset, and a sound and light alarm will be issued when the alarm threshold or block is blocked. The product implementation standard is "JJG 100-2006 direct reading X, γ radiation personal dose equivalent (rate) monitoring instrument”. A production license for manufacturing measuring instruments.

FJ-3501 personal dosimeter is operated by a single machine. The dose and dose rate data can be read directly by LCD. Within the measurement range, all kinds of threshold alarm values can be set arbitrarily, and sound and light alarm will be issued to remind the staff to pay attention to safety. The instrument is equipped with alarm of dose and dose rate exceeding threshold, alarm of working overtime, alarm of detector block, alarm of battery undervoltage and alarm of memory gradually full.

Personal dosimeter FJ3501 type main technical indicators meet the national standards and international standards, is the current domestic similar instruments in the strong function, small volume, low power consumption with a pocket instruments, it is widely used in nuclear military industry, nuclear power plants, industrial nondestructive flaw detection, isotope application and cobalt hospital treatment, occupational protection, residents around the plant background radiation level monitoring and other fields.

 

Technical parameters:

Detector: GM counter (compensated)

Measurement range: cumulative dose equivalent: Hp(10)0.0μsv-9999msv

Dose equivalent rate: Hp(10)0.1μSv/h-100mSv/h

Relative error: <±15% (137Cs) (10uSv/h-50msv/h)

Energy response: 50KeV-1.3MeV, error of 30%

Angle response: the reference 137Cs does not exceed the calibration direction of ±30% at 0°-90°

Alarm function: the alarm threshold can be set continuously, the alarm valve value is greater than the set alarm threshold. When the counter is blocked, continuous alarm is constant, and the alarm sound intensity is greater than 80dB at 30cm.

Power consumption: a 1.5v alkaline battery section (no. 7 battery) environment under the environment, continuous use of 72 hours, power consumption < 3mW.

Appearance size: 50 (style)×72 (long)×14 (thick)

Weight: 60g

 

Characteristic curve

 

Energy response characteristics

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 0

 

Dose-rate response characteristics:

 

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 1

 

Angular response characteristics

 

Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 2Light Weight X-Ray Flaw Detector , HUATEC FJ-3501 Personal Dosimeter 3

 

Performance characteristics:

Small size, light weight, with back clamp, easy to carry

The sensitivity of the instrument is high, which also has a response to the environment background. Overload blocking alarm

Use a common battery, low power consumption

Strong resistance to electromagnetic interference

 

Application field:

It is applicable to the protection and personal dose monitoring of workers in the fields of industrial nondestructive testing, isotope application, nuclear industry, hospital, railway, civil aviation, environmental protection and other radioactive applications