• HUATEC GROUP CORPORATION
    Bob
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    William
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    tom
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
  • HUATEC GROUP CORPORATION
    Leo
    Blok Uji Kalibrasi Astm E114-15 Inch Tipe 1018 Baja Karbon Mini Iiw 2
Kontak Person : Noah
Nomor telepon : +8613911115555
Ada apa : +8613910983110

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

Tempat asal Beijing
Nama merek HUATEC
Sertifikasi ISO, CE, GOST
Nomor model HGS-10C
Kuantitas min Order 1 PCS
Kemasan rincian paket standar ekspor
Waktu pengiriman 1-4 hari
Syarat-syarat pembayaran T/T, PayPal, Western Union
Menyediakan kemampuan 500pcs per bulan

Hubungi saya untuk sampel gratis dan kupon.

Ada apa:0086 18588475571

Wechat wechat: 0086 18588475571

Skype: sales10@aixton.com

Jika Anda memiliki masalah, kami menyediakan 24 jam bantuan online.

x
Detail produk
Rentang pengujian 0~200mT~2000mT Keakuratan ± 5%
Kepekaan 0,01mT, 0,1mT Medan Magnet AC 50-200Hz
DC/AC Sakelar DC/AC Satuan Perubahan Satuan mT/Gs
Ukuran 150mm×70mm×30mm Berat badan 500 g
Menyoroti

mt test specimen

,

magnetic strenght meter

Tinggalkan pesan
Deskripsi Produk

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter

 

Introduction

The Tesla meter is a special instrument used for inspecting & checking flux density, which is also one of the most universally devices in the field of magnetic measurement.

Model HGS10C digital Tesla meter is controlled by the SCM, which is suitable for handle operation. It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’s person. It is characterized by its wide measuring range, simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value, As mT or Gs unit of display can be change over, Measuring range of 200mT or 2000mT can be chose, and others that as resetting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours.

 

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 0

 

Application

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface

 

Main Technical Parameters

 

Rang: 0~200mT~2000mT

Accuracy: ±2%

Sensitivity: 0.01mT, 0.1mT

AC Magnet Field: 50-200Hz

Temperature of environment: 5℃-40℃

Relative humidity: 20%-80%(no condensation)

Power Supply: Battery 9V, constant DC power

Dimension: 150mm×70mm×30mm

Weight: N.W: 500g G.W:900g

Display: 4½ LCD

 

Shape of the device:

  1. Sensor Connecting
  2. LED Screen
  3. Zero/Reset Reading

 

Features

Shape of the device:

Peak/Real Value Switch

DC/AC Switch

Range Changing

mT/Gs Unit Changing

Power On/Off

External power supply socket

Sensor Connecting

LED Screen

Zero/Reset Reading

 

Operation request:

  1. Magnetic field distribution of material surface
  2. Working magnetic field produced fro some instrument that as iron-removing device,magnet-selecting machine, magnet chuck, magnet spool and demagnetizing coil
  3. Leakage Magnetic iron-surface
  4. Do not use the instrument in unappropriate conditions.
  5. If you find the value of testing were error in the status ofmeasurement,

    you could loosened the handle of the probe to adjust the screw of the resistance tinily.

  6. If don’t ensure that the instrument is operated correctly described below, there would be error or mistake

  7. Don’t attempt to repair, or disassemble, and any reconstruct this instrument.

  8. Use only recommended power accessories.
  9. Don’t connect the terminals of the outer power supply reversely. the inner is plus, the outer is minus.
  10. Don’t drop this instrument or the probe down ground. It’ll be damaged by strong vibration.
  11. Do not allow hands or other objects with dirt to touch the probe.
  12. Avoid using, placing or storing the instrument in places subject to strong sunlight or high temperature, so as to humidity, water, oil, rust air, vibration and others.

Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 1Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 2Digital Magnetic Field Strength Meter Hall Effect Tesla Meter, Magnetic Field Intensity Meter 3